Lead Engineer (Electrical Bias)

Position Sought Engineer
Name CAN  17689
Lives in Radcliffe, Manchester
Qualifications City & Guilds Electrical Installations Parts 1 and 2

17th Edition

NEBOSH

F-Gas

LV AP

Previous Employers Carillion

Sudlow’s

Availability 4 weeks
General Notes if Applicable  

Qualifications:

  • City & Guilds Electrical Installations Parts 1 & 2
  • BS 2391 Electrical Installation, Inspection, Test & Certification
  • BS 2400 Electrical Installation, Design, Erection & Verification
  • Electronics Servicing Part 1
  • 17th Edition Wiring Regulations
  • 2079 F Gas Cat 4
  • JIB Installation Electrician – Technician
  • Low Voltage Authorised Person
  • Installation & servicing of Domestic Unvented Hot Water Storage Systems
  • NEBOSH National Certificate in Construction Safety & Health
  • UKATA Asbestos Awareness
  • Legionella Awareness
  • St John Ambulance Emergency First Aid at Work
  • PASMA Mobile Access Tower
  • IPAF MEWP & SPB
  • CCTV Level 1 & 2 Training
  • BFPSA BS 5839 Fire Detection Systems Maintenance & Design

 

Profile:

  • I am a pro-active professional with extensive practical and supervisory experience in electrical installation and maintenance that thrives in challenging environments. I also have excellent organisational and problem solving skills
  • I have a proven ability to inspire, motivate and lead multi-skilled teams whilst ensuring the sites remain compliant with all of the relevant health, safety and quality standards
  • I am experienced in delivering commercial projects on time from the initial site survey and quotation to client hand-over
  • To find a challenging position that will make best use of my existing skills, qualifications and experience whilst enabling further personal development

Employment History:

XXX                                                                 Lead Engineer

October 2018 – Present

  • Completion of M&E PPM tasks, electrical reactive repairs and minor installations in RBS business critical buildings
  • Audit and upkeep of site specific maintenance records and documents
  • Completion of inspections and certification to BS 5266, 2016 and BS 7671, 2008
  • Liaison and supervision of Sub-Contractors
  • Review of sub-contractor risk assessments and method statements
  • Preparation and management of work permits for sub-contractors

 

XXX                                                                 Mobile Maintenance Engineer

February 2018 – October 2018

  • Completion of M&E PPM tasks, electrical reactive repairs and minor installations in commercial buildings
  • Audit and upkeep of site specific maintenance records and documents
  • Completion of inspections and certification to BS 5266, 2016 and BS 7671, 2008
  • Thermal image inspection and reporting of commercial electrical installations
  • Compilation of specification and quotation for remedial and extra works

 

Carillion                                                          Mobile Maintenance Electrician

                                                                        – NICEIC Qualifying Supervisor

January 2015 – February 2018

  • Completion of M&E PPM tasks, electrical reactive repairs and minor installations in commercial buildings
  • Completion of certification to BS 5266, 2016 and BS 7671, 2008
  • Supervision of sub-contractors
  • Audit of electrical installations, certificates, Engineers and Electricians. Support and advise Engineers and Electricians on electrical installation and maintenance

 

Sudlows Ltd                                                   Maintenance Supervisor

June 2014 – December 2014

  • Completion of electrical PPM tasks, electrical reactive repairs and minor installations in data centres
  • Completion of certification to BS 5266, 2011 and BS 7671, 2013
  • Supervision of multi-trade sub-contractors
  • Writing risk assessments and method statements for electrical tasks in addition to reviewing risk assessments and method statements submitted by multi-trade sub-contractors
  • Preparation of quotations for additional work
  • Developed positive relationships with clients whilst ensuring their satisfaction with the services provided

 

Carillion                                                          Mobile Maintenance Electrician

2011 – 2014 

  • Completion of M&E PPM tasks, electrical reactive repair and minor installations
  • Statutory testing of emergency lighting installations and report writing to BS 5266-1, 2011 and BS 7671, 2013
  • Supervision of sub-contractors
  • Developed positive relationships with clients, to ensure their satisfaction with the service provided and prepared quotations for additional work

  

INS Sudlows Ltd                                            Site Manager / Electrician

2009 – 2011 

  • A key role to deliver a contract for the upgrade of the electrical supply to a Co-operative Group site valued at £0.5 million
  • Managed from site all aspects of the construction and refurbishment of data centres that incorporated UPS and generator back up supplies
  • Responsible for the setup and maintenance of sites in accordance with CDM regulations
  • Participated in regular progress meetings hosted by the client
  • Supervision of all M&E, building and civil engineering activities on site to ensure quality and safety compliance
  • Procurement of labour, materials and plant for electrical installations
  • Prepared work permits and periodically reviewed risk assessments and method statements submitted by INS
  • Sudlows and their sub-contractors
  • Inspection, test and verification of certification for commercial electrical installations in compliance with BS 7671, 2008

 

NG Bailey / Bailey Maintenance                   Service Leader / Qualifying Supervisor

2007 – 2009

  • Supervision of employees and sub-contractors on a P21 contract at Trafford General Hospital (£2.5 million)
  • Prepared work permits, risk assessments and method statements for approval by the Trust
  • Prepared progress reports to distribute at regular site meetings with the main contractor. BAM, and their sub-contractors
  • Prepared M&E O&M manuals for submission to the client
  • Supervision of M&E maintenance
  • Maintained records and certificates for compliance with NICEIC registration
  • Provided technical support for employees to assist in resolving problems on-site
  • Developing positive relationships with clients, ensuring their satisfaction with the service provided and preparing quotations for additional works

 

TOM Gallagher Ltd                                         Qualifying Supervisor

2004 – 2007

  • Managed teams of up to14 Electricians and sub-contractors employed on commercial and domestic installations including the installation of electrical supplies and controls for automated HGV turntables
  • Played a key role in the maintenance of NICEIC registration whilst also ensuring that employees and sub-contractors adhered to safe working practices
  • Provided guidance for Electricians and arranged external training them to keep up with changes in relevant legislation
  • Inspection and reporting on electrical, emergency lighting and fire alarm installations
  • Conducting site surveys on behalf of clients, preparing quotes for small projects valued up to £50k and managing them through to a successful and timely completion

 

EIC Ltd                                                            Service Engineer

2002 – 2004

  • Responsible for the installation, repair, inspection and testing of electrical, fire and emergency lighting installations on commercial properties and supermarkets
  • Preparing detailed condition reports with recommendations as well as producing certificates in line with British Standards 

 

Maximum Protection Services Ltd               Installation / Qualifying Supervisor

2000 – 2002

  • Working on a wide range of projects, including new build and refurbishment, valued up to £100k with specific responsibility for the design, inspection and supervision of electrical installations
  • Coordinating up to ten employees and sub-contractors and ensuring they are focused on completing electrical and CCTV projects on time and to the highest standard of workmanship

 

Self-employed                                                Electrician

1989 – 2000

  • Undertaking general design, installation, inspection and repair works for Wilmot Dixon, Lyons Electrical Engineers, Security Solutions Ltd and M.F. Kent Ltd
  • Actively involved in major projects including the installation of electrical works at Christies Hospital and the new terminal building at London Gatwick Airport

  

TOM Croft Ltd                                                 Apprentice Electrician

1984 – 1989

 

Additional Information:

Interests:

  • Family Activities, Live Music, Swimming, Rugby

Other: